Total : 40W
Dimension (L*W*H) : 125*75*30 mm
Input : 110VAC / 220VAC
Output : +5VDC/5A , +12VDC/2A , -12VDC/0.5A
We can change any output voltage and current.
|
1.INTRODUCTION:
|
| THIS
IS AN POWER SUPPLY OF SPECIFICATION. |
|
2.INPUT
:
|
| 2.1
AC INPUT VOLTAGE |
:
85VAC to 264VAC |
|
2.2
AC INPUT FREQUENCY
|
:
47 TO 440 HZ.
|
|
2.3
AC INPUT CURRENT
|
:
2A RMS MAX. FOR 115 VAC.
|
|
1A
RMS MAX. FOR 230 VAC.
|
| 2.4
MAX. INRUSH CURRENT |
:
12A FOR 115 VAC COLD START.
|
|
24A
FOR 230 VAC COLD START.
|
|
3.OUTPUT
:
|
|
3.1
CENTRAL VOLTAGE
|
:
+5V DC
|
+12V
DC |
-12V
DC
|
|
3.2
VOLTAGE REGULATION
|
:
+/-2%
|
+/-5% |
+/-5%
|
|
3.3
MAX. CURRENT
|
:
5.0A
|
2.0A |
0.5A
|
|
3.4
RATED CURRENT
|
:
3.0A
|
2.0A |
0.35A
|
|
3.5
MIN. CURRENT
|
:
0.0A
|
0.0A |
0.0A
|
|
3.6
RIPPLE & NOISE
|
:
50mV
|
120mV |
120mV
|
|
3.7
LINE REGULATION
|
:
+/-1%
|
+/-1% |
+/-1%
|
|
3.8
LOAD REGULATION
|
:
+/-5%
|
+/-10% |
+/-10%
|
|
3.9
NATURAL CONVECTION COOLED
|
:
40W CONTINUOUS MAXIMUM.
|
|
3.10
FORCED AIR 20CFM AT 1 ATMOSPHERE
|
:
50W CONTINUOUS MAXIMUM.
|
|
4.ELECTRICAL
SPECIFICATIONS:
|
|
4.1
EFFICIENCY
|
:
70% AT FULL LOAD AND NOMINAL INPUT VOLTAGE.
|
|
4.2
RISE TIME
|
:
20mS MAX.
|
|
4.3
HOLD UP TIME
|
:
12mS AT FULL LOAD AND NOMINAL INPUT VOLTAGE.
|
|
4.4
STABILITY
|
:
+/-0.5% AFTER 24 HOURS WARM UP.
|
| 4.5
OVERSHOOT |
:10%
MIN. ABOVE THE NOMINAL VOLTAGE. |
|
5.
OUTPUT PROTECTION :
|
|
5.1
SHORT CIRCUIT PROTECTION :
|
ALL
OUTPUT EQUIPPED WITH SHORT CIRCUIT PROTECTION.
|
| 5.2
OVER CURRENT PROTECTION : |
:
150% MAX. |
|
6.
ENVIRONMENTAL :
|
|
6.1
OPERATING TEMPERATURE :
|
0 TO +50 DEGREE C.
|
|
6.2
OPERATING
HUMIDITY
|
:20%
TO 90% RH.
|
|
6.3
OPERATING ALTITUDE
|
:
TO 10,000 ft.
|
|
6.4
STORAGE TEMPERATURE
|
-20 TO +85 DEGREE C.
|
|
6.5
STORAGE HUMIDITY
|
:
10% TO 90% RH.
|
|
6.6
STORAGE
ALTITUDE
|
TO
50,000 ft
|
|
6.7
VIBRATION
|
:10-500Hz,.2G
10MIN/TCYLE ,PERIOD FOR 60MIN. EACH AXES.
|
|
6.8
COOLING
|
:
FREE AIR CONVECTION.
|
|
7.RELIABILITY:
|
|
7.1
MTBF
|
:170K
HOURS AT MAX. LOAD , NORMAL LINE AND 25
DEGREE C.
|
|
8.MECHANICAL:
|
|
8.1
PHYSICAL DIMENSIONS
|
:
125(L) x 75(W) x 30(H)mm .
|
|
8.2
AC CONNECTOR
|
:
3.96mm
|
|
8.3
DC CONNECTORS
|
:
3.96mm
|
|
9.
SAFETY STANDARD :
|
:
MEETS TUV EN 60950 ,/ UL1950 / CSAC22.2-220
|
|
10.
EMI STANDARD :
|
:
MEET CE FCC.
|
|
11.
DIELECTRIC WITH STAND (HI-POT) TEST :
|
|
11.1
INPUT TO OUTPUT
|
:
1500VAC FOR 1 SEC.
|
|
11.2INPUT
TO GROUND
|
:
1500VAC FOR 1 SEC.
|
|
12.
INSULATION RESISTANCE :
|
|
12.1
INPUT TO OUTPUT
|
:
500VDC / 50Mohms.
|
|
12.2
INPUT TO GROUND
|
:
500VDC / 50Mohms.
|
|