Total : 12W
Dimension : 130*70*25 mm
Input : 110VAC / 220VAC
Output : +5VDC/2A, +12VDC/0.3A, -12VDC/0.3A
We can change any output voltage and current.
|
Input
|
| Input range |
85-264VAC or
120-300VDC |
| Frequency |
47-440Hz |
| Inrush current |
<18A
peak @ 230VAC
<36A
peak @ 230VAC
|
| Efficiency |
70%
typical at full load |
| EMI filter |
FCC
Class B conducted |
| Safety ground
leakage current |
<0.5mA
@ 50/60Hz,264VAC input |
|
Output
|
| DC output |
+5VDC |
+12VDC |
-12VDC |
| 2A |
0.3A |
0.3A |
| Maximum power |
12W
for convection
20W
with 30 CFM forced air
|
| Adjustment range |
-5,+10%
minimum |
| Cross regulation |
+-2% on
output 1;+-5% on output 2,3 |
| Hold-up time |
20ms @
40w load ; 115VAC nominal line. |
| Overload protection |
5.7 to
6.7 VDC on main output |
| Remote sense |
Compensates
for 0.5V lead drop min.
Will
operate without remote sense connected.
Reverse
connection protected
|
.
|